Witthoft S, Kesner K, Poston RW. J. Perform. Constr. Facil. 2008; 22(6): 364-372.

Copyright

(Copyright © 2008, American Society of Civil Engineers)

DOI

10.1061/(ASCE)0887-3828(2008)22:6(364)

PMID

unavailable

Abstract

The results of a multifaceted investigation into large-amplitude vibrations of bridge stay cables are presented. The vibration of the stay cables occurred under light rain and wind conditions, and resulted in low-frequency, large-amplitude oscillations having recorded displacements of over 24 in. (0.6 m). Due to concerns about the implications of the vibrations on the integrity and durability of the stay cables and observed damage to stay-cable anchorage components, an investigation and repair program was developed. The final repair program arose from an investigation that combined the talents of practicing engineers, the Texas Department of Transportation, and representatives from four universities. Ultimately, a combination of supplemental hydraulic dampers and cable restrainers were used to mitigate the vibrations. This paper describes the results of the investigation and presents the practice-based methodology used to develop the implemented repair program.