SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Denoyer A, Denoyer L, Halfon J, Majzoub S, Pisella PJ. J. Cataract Refract. Surg. 2009; 35(3): 496-503.

Affiliation

Department of Ophthalmology, Bretonneau University Hospital, Tours, France. alexandre.denoyer@gmail.com

Copyright

(Copyright © 2009, American Society of Cataract and Refractive Surgery and European Society of Cataract and Refractive Surgeons, Publisher Elsevier Publishing)

DOI

10.1016/j.jcrs.2008.11.032

PMID

19251144

Abstract

PURPOSE: To compare the quality of vision with an aspheric intraocular lens (IOL) with no aberration and an IOL with negative spherical aberration. SETTING: Bretonneau University Hospital, Tours, France. METHODS: Patients scheduled for cataract surgery were randomly chosen to bilaterally receive a SofPort Advanced Optics IOL with no aberration (no-aberration IOL group) or a Tecnis Z9000 IOL with negative spherical aberration (negative-aberration IOL group). Six-month postoperative outcomes included patient-centered visual disability assessed with the Activities of Daily Vision Scale (ADVS), contrast sensitivity testing, and wavefront aberration analysis. RESULTS: There was no difference in the overall ADVS score between the 2 groups (P = 0.07); however, the negative-aberration IOL group had a better night-driving score (mean 82.7 +/- 15.1 [SD] versus 66.4 +/- 7.6) (P<.001) and the no-aberration IOL group had a better corrected near-vision score (mean 96.5 +/- 6.2 versus 86.2 +/- 13.2) (P<.001). Mesopic contrast sensitivity was significantly better in the negative-aberration IOL group at intermediate and high frequencies; the no-aberration IOL group performed better under photopic conditions at intermediate frequencies. There was significantly higher spherical aberration (mean 0.11 +/- 0.05 microm versus 0.01 +/- 0.06 microm; P = .001) and lower 3rd-order coma (mean 0.09 +/- 0.06 microm versus 0.15 +/- 0.06 microm; P<.001) in the no-aberration IOL group than in the negative-aberration IOL group, which had better MTF. CONCLUSIONS: Bilateral implantation of an IOL with no aberration resulted in better quality of near vision. A negative spherical aberration IOL provided better night-driving vision and improvements in mesopic contrast sensitivity and MTF.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print