SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Schmitz S, Dick HB, Krummenauer F, Schwenn O, Krist R. Br. J. Ophthalmol. 2000; 84(10): 1109-1112.

Affiliation

Department of Ophthalmology, University of Mainz, Mainz, Germany.

Copyright

(Copyright © 2000, BMJ Publishing Group)

DOI

unavailable

PMID

11004093

PMCID

PMC1723267

Abstract

BACKGROUND: Standard examination of contrast sensitivity under conditions of glare disability is performed with incandescent light. A new halogen glare test that simulates glare as seen with oncoming vehicle headlights was used to measure glare disability in patients implanted with multifocal and monofocal intraocular lenses (IOLs). METHODS: 28 patients with an average age of 69 years (SD 12 years) were implanted with a monofocal IOL (SI-40NB, Allergan) and 28 patients with an average of 66 years (12 years) were implanted with a refractive multifocal IOL (Array-SA-40N, Allergan). All patients were followed for 5 months postoperatively. Contrast sensitivity at four spatial frequencies (3, 6, 12, and 18 cycles per degree, cpd) with and without a glare source were measured using the halogen glare test (CSV-1000 HGT). Statistical analysis was performed using the two sample Wilcoxon test. The local significance level was set at 0.05. RESULTS: When tested at the lowest spatial frequency (3 cpd) without halogen glare, contrast sensitivity was lower in the multifocal group than in the monofocal group (p=0.0292). With additional glare, there was no difference between both groups. At all other spatial frequencies (6, 12, and 18 cpd), when tested without halogen glare (6 cpd, p=0.5250; 12 cpd, p=0.8483; 18 cpd, p=0.9496) and with moderate (3 cpd, p=0.7993; 6 cpd, p=0.4639; 12 cpd, p=0.7456; 18 cpd, p=1.0) and high halogen glare (3 cpd, p=0. 1513; 6 cpd, p=0.2016; 12 cpd, p=0.3069; 18 cpd, p=0.9933), there was no statistically significant difference between groups. Patients in both groups of age 70 or older had reduced contrast sensitivity without halogen glare and with moderate and strong glare. When monofocal and multifocal patients older than 70 years of age were analysed separately, there was no statistically significant difference in contrast sensitivity with and without glare. Astigmatism >1 dioptre had no significant influence on contrast sensitivity and glare disability when monofocal and multifocal eyes were compared. CONCLUSION: Reduced contrast sensitivity was found in the multifocal group only at the lowest spatial frequency without halogen glare. The monofocal and multifocal groups had no statistically significant differences in contrast sensitivity with moderate and strong glare. These results suggest no difference in glare disability induced by halogen light similar to oncoming vehicle headlights for patients implanted with monofocal and multifocal IOLs.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print