SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Goleb JA, Midkiff CR. J. Forensic Sci. 1975; 20(4): 701-707.

Copyright

(Copyright © 1975, American Society for Testing and Materials, Publisher John Wiley and Sons)

DOI

unavailable

PMID

1176924

Abstract

Critical comparisons of Ba and Sb in firearms discharge residue were made on samples collected by three independent collection technqiues. Collection materials studied were transparent adhesive tape, (Scotch Brand), a solution of cellulose acetate in acetone ("Film Lift"), and plastic-shafted cotton swabs wetted with dilute nitric acid. Flameless atomic absorption analyses were performed with a Jarrell-Ash Model 810 instrument equipped with a tantalum strip atomizer. Tape and cotton swabs gave comparable positive indications of residue, with frequencies of 90 and 80%, respectively. The plastic Film Lift gave fewer positives, with a frequency of 50%. With the transparent tape lift, gunshot residue particles are discernible, making nondestructive microscopic identification possible prior to destructive elemental analysis.