SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Tam M, Pilon P, Zaknoun H. J. Forensic Sci. 2013; 58(5): 1336-1340.

Affiliation

Science and Engineering Directorate, Canada Border Services Agency, 79 Bentley Avenue, Ottawa, K2E 6T7, Ontario, Canada.

Copyright

(Copyright © 2013, American Society for Testing and Materials, Publisher John Wiley and Sons)

DOI

10.1111/1556-4029.12240

PMID

23879631

Abstract

Trace explosive test surfaces are often required for the evaluation of trace detection equipment to determine the equipment performance. Test surfaces of C-4, Detasheet, Semtex-H, TNT, and HMTD were prepared by transferring trace amount of explosive deposited on polytetrafluoroethylene (PTFE) transfer strips onto different surfaces (Kraft paper, hard plastic, woven fabric, and soft vinyl). The amount of explosive transferred was deduced from the amount of explosive remaining on the PTFE strips after transfer, as quantified by direct analysis using tandem mass spectrometry with thermal desorption. From the data set of over 2000 transfers, we experienced lower transfer efficiency for Semtex-H and Detasheet, and for soft vinyl and hard plastic. However, the rapid quantification mass spectrometric method allowed the transfer efficiency to be determined for all test surfaces used in an evaluation of trace explosive detectors, thereby permitting only the test surfaces with desired transfer to be accepted for the assessment.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print