SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Bourke AK, O'Donovan K, Clifford A, Olaighin G, Nelson J. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2011; 2011: 7896-7899.

Copyright

(Copyright © 2011, IEEE (Institute of Electrical and Electronics Engineers))

DOI

10.1109/IEMBS.2011.6091947

PMID

22256171

Abstract

This study aims to determine an optimum estimate for the gravitational vector and vertical acceleration profiles using a body-worn tri-axial accelerometer during falls and normal activities of daily living (ADL), validated using a camera based motion analysis system. Five young healthy subjects performed a number of simulated falls and normal ADL while trunk kinematics were measured by both an optical motion analysis system and a tri-axial accelerometer. Through low-pass filtering of the trunk tri-axial accelerometer signal between 1Hz and 2.7Hz using a 1(st) order or higher, Butterworth IIR filter, accurate gravity vector profile can be obtained using the method described here. Results: a high mean correlation (≥0.83: Coefficient of Multiple Correlations) and low mean percentage error (≤2.06m/s(2)) were found between the vertical acceleration profile generated from the tri-axial accelerometer based sensor to those from the optical motion capture system. This proposed system enables optimum gravity vector and vertical acceleration profiles to be measured from the trunk during falls and normal ADL.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print