SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Eckner JT, Kutcher JS, Richardson JK. J. Athl. Train. 2010; 45(4): 327-332.

Affiliation

Department of Physical Medicine, University of Michigan, Ann Arbor, MI 48108, USA. jeckner@med.umich.edu

Copyright

(Copyright © 2010, National Athletic Trainers' Association (USA))

DOI

10.4085/1062-6050-45.4.327

PMID

20617905

PMCID

PMC2902024

Abstract

CONTEXT: Evidence suggests that concussion prolongs reaction time (RT). We have developed a simple, reliable clinical tool for measuring reaction time that may be of value in the assessment of concussion in athletes.

OBJECTIVE: To compare baseline values of clinical RT (RT(clin)) obtained using the new clinical reaction time apparatus with computerized RT (RT(comp)) obtained using a validated computerized neuropsychological test battery.

DESIGN: Cross-sectional study. SETTING: Data were collected during a National Collegiate Athletic Association Division I collegiate football team's preparticipation physical examination session. PATIENTS OR OTHER PARTICIPANTS: Ninety-four Division I collegiate football players. MAIN OUTCOME MEASURE(S): The RT(clin) was measured using a 1.3-m measuring stick embedded in a weighted rubber disk that was released and caught as quickly as possible. The RT(comp) was measured using the simple RT component of CogState Sport.

RESULTS: For the 68 athletes whose CogState Sport tests passed the program's integrity check, RT(clin) and RT(comp) were correlated (r = 0.445, P <.001). Overall, mean RT(clin) was shorter and less variable than mean RT(comp) (203 +/- 20 milliseconds versus 268 +/- 44 milliseconds; P <.001). When RT(clin) and RT(comp) were compared between those athletes with (n = 68) and those without (n = 26) valid CogState Sport test sessions, mean RT(clin) was similar (202 +/- 19 milliseconds versus 207 +/- 23 milliseconds; P =.390), but mean RT(comp) was different (258 +/- 35 milliseconds versus 290 +/- 55 milliseconds; P =.009).

CONCLUSIONS: The RT(clin) was positively correlated with RT(comp) and yielded more consistent reaction time values during baseline testing. Given that RT(clin) is easy to measure using simple, inexpensive equipment, further prospective study is warranted to determine its clinical utility in the assessment of concussion in athletes.

Keywords: American football;


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print