Journal Article

Citation

Allison MA, Kang YS, Maltese MR, Bolte JH, Arbogast KB. Ann. Biomed. Eng. 2014; 43(8): 1896-1906.

Affiliation

The Center for Injury Research and Prevention, The Children's Hospital of Philadelphia, 3535 Market St. Suite 1150, Philadelphia, PA, 19104, USA, maall@seas.upenn.edu.

Copyright

(Copyright © 2014, Holtzbrinck Springer Nature Publishing Group)

DOI

10.1007/s10439-014-1197-z

PMID

25476162

Abstract

Helmet-based instrumentation is used to study the biomechanics of concussion. The most extensively used systems estimate rotational acceleration from linear acceleration, but new instrumentation measures rotational velocity using gyroscopes, potentially reducing error. This study compared kinematics from an accelerometer and gyroscope-containing system to reference measures. A Hybrid III (HIII) adult male anthropometric test device head and neck was fit with two helmet brands, each instrumented with gForce Tracker (GFT) sensor systems in four locations. Helmets were impacted at various speeds and directions. Regression relationships between GFT-measured and reference peak kinematics were quantified, and influence of impact direction, sensor location, and helmet brand was evaluated. The relationship between the sensor output and the reference acceleration/velocity experienced by the head was strong. Coefficients of determination for data stratified by individual impact directions ranged from 0.77 to 0.99 for peak linear acceleration and from 0.78 to 1.0 for peak rotational velocity. For the data from all impact directions combined, coefficients of determination ranged from 0.60 to 0.80 for peak resultant linear acceleration and 0.83 to 0.91 for peak resultant rotational velocity. As expected, raw peak resultant linear acceleration measures exhibited large percent differences from reference measures. Adjustment using regressions resulted in average absolute errors of 10-15% if regression adjustments were done by impact direction or 25-40% if regressions incorporating data from all impact directions were used. Average absolute percent differences in raw peak resultant rotational velocity were much lower, around 10-15%. It is important to define system accuracy for a particular helmet brand, sensor location, and impact direction in order to interpret real-world data.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print