SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Gazit E, Buchman AS, Dawe R, Curran TA, Mirelman A, Giladi N, Hausdorff JM. Gait Posture 2019; 76: 128-135.

Affiliation

Center for the study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Israel; Rush Alzheimer's Disease Center, Rush University Medical Center, Chicago, United States; Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, United States; Sagol School of Neuroscience, Tel Aviv University, Israel; Department of Physical Therapy, Sackler Faculty of Medicine, Israel.

Copyright

(Copyright © 2019, Elsevier Publishing)

DOI

10.1016/j.gaitpost.2019.11.007

PMID

31760316

Abstract

BACKGROUND: Walking is a volitional behavior that requires planning and initiation before a step is observed. Following a signal to begin walking, studies of gait initiation in specialized labs have identified three phases that occur during the transition from a standing position via anticipatory postural adjustment (APA) to the first step. Routine instrumented gait testing outside of the laboratory setting focuses on gait execution and does not include gait initiation measures. RESEARCH QUESTION: Can a single IMU sensor be used for performing gait initiation evaluations outside the lab? METHODS: We recorded walking in young (N = 41) and older (N = 26) adults using an instrumented gait mat while they were wearing a 3D accelerometer on their lower back. Subjects were instructed to begin walking following an auditory signal. An algorithm was developed to extract the following measures from the acceleration signal: gait initiation time, measured from the start of the auditory cue to begin walking and ends at the heel-strike of the swing leg, time-to-APA (reaction time), APA duration and swing time (execution of the first step).

RESULTS: Intraclass correlation coefficient analysis showed good to excellent agreement between gait initiation metrics obtained with the gait mat and the wearable sensor (mean 0.88, range [0.75-0.96]). Except for swing time, all measures were longer in the older subjects, compared to the young adults (p < 0.01). SIGNIFICANCE: Extracting gait initiation measures from routine instrumented gait testing may facilitate studies that can better determine the extent to which impaired gait planning and execution contribute to mobility impairments.

Copyright © 2019 Elsevier B.V. All rights reserved.


Language: en

Keywords

accelerometer; aging; anticipatory postural adjustment; gait; inertial measurement units

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print