@article{ref1,
title="Breathalyzer accuracy in actual law enforcement practice: a comparison of blood- and breath-alcohol results in Wisconsin drivers",
journal="Journal of forensic sciences",
year="1987",
author="Harding, P. and Field, P. H.",
volume="32",
number="5",
pages="1235-1240",
abstract="Breathalyzer and blood-alcohol results from drivers arrested for operating a motor vehicle while intoxicated and for related offenses were compared during a two-year period. Four hundred and four pairs of breath- and blood-alcohol results from specimens collected within 1 h of each other were studied. Blood-alcohol concentrations ranged from zero to 0.421% weight per volume (w/v). Breath-alcohol concentrations ranged from zero to 0.44 g/210 L. The mean Breathalyzer result was 0.16 g/210 L. The mean blood-alcohol result was 0.176% w/v. Compared to the blood-alcohol result, Breathalyzer results were lower by more than 0.01 g/210 L 61% of the time, within 0.01 g/210 L 33% of the time, and higher by more than 0.01 g/210 L 6% of the time.<p /><p>Language: en</p>",
language="en",
issn="0022-1198",
doi="",
url="http://dx.doi.org/"
}