@article{ref1,
title="Validation of two devices for evaluation of human psychomotor performance",
journal="Perceptual and motor skills",
year="1991",
author="Kunsman, G. W. and Manno, J. E. and Przekop, M. A. and Manno, B. R.",
volume="73",
number="1",
pages="255-264",
abstract="The Pursuit Meter III (PM III) and the Simultaneous Hand and Foot Tracking (SHAFT) task are microcomputer-based devices for the evaluation of human psychomotor performance. Both devices are pursuit-tracking tasks. The primary task (PM III) requires a subject superimpose a line over a computer-generated sine wave. The computer wave is black and the subject's wave is red. The vertical position of the subject's wave is determined by a joystick controller. The SHAFT adds a second simultaneous tracking task (FTT) that is operated by means of a foot control. Ten naive subjects performed either device for 5 sessions/day over a three-day period. Each session consisted of 5 sweeps of the sine wave pattern. Mean performance on both tasks generally improved over the assessment period, and differential stability was reached within 10 sweeps for each device.<p /> <p>Language: en</p>",
language="en",
issn="0031-5125",
doi="",
url="http://dx.doi.org/"
}