@article{ref1,
title="Comparative study of aspheric intraocular lenses with negative spherical aberration or no aberration",
journal="Journal of cataract and refractive surgery",
year="2009",
author="Denoyer, Alexandre and Denoyer, Ludovic and Halfon, Jérémie and Majzoub, Samuel and Pisella, Pierre-Jean",
volume="35",
number="3",
pages="496-503",
abstract="PURPOSE: To compare the quality of vision with an aspheric intraocular lens (IOL) with no aberration and an IOL with negative spherical aberration. SETTING: Bretonneau University Hospital, Tours, France. METHODS: Patients scheduled for cataract surgery were randomly chosen to bilaterally receive a SofPort Advanced Optics IOL with no aberration (no-aberration IOL group) or a Tecnis Z9000 IOL with negative spherical aberration (negative-aberration IOL group). Six-month postoperative outcomes included patient-centered visual disability assessed with the Activities of Daily Vision Scale (ADVS), contrast sensitivity testing, and wavefront aberration analysis. RESULTS: There was no difference in the overall ADVS score between the 2 groups (P = 0.07); however, the negative-aberration IOL group had a better night-driving score (mean 82.7 +/- 15.1 [SD] versus 66.4 +/- 7.6) (P<.001) and the no-aberration IOL group had a better corrected near-vision score (mean 96.5 +/- 6.2 versus 86.2 +/- 13.2) (P<.001). Mesopic contrast sensitivity was significantly better in the negative-aberration IOL group at intermediate and high frequencies; the no-aberration IOL group performed better under photopic conditions at intermediate frequencies. There was significantly higher spherical aberration (mean 0.11 +/- 0.05 microm versus 0.01 +/- 0.06 microm; P = .001) and lower 3rd-order coma (mean 0.09 +/- 0.06 microm versus 0.15 +/- 0.06 microm; P<.001) in the no-aberration IOL group than in the negative-aberration IOL group, which had better MTF. CONCLUSIONS: Bilateral implantation of an IOL with no aberration resulted in better quality of near vision. A negative spherical aberration IOL provided better night-driving vision and improvements in mesopic contrast sensitivity and MTF.<p /> <p>Language: en</p>",
language="en",
issn="0886-3350",
doi="10.1016/j.jcrs.2008.11.032",
url="http://dx.doi.org/10.1016/j.jcrs.2008.11.032"
}