@article{ref1,
title="Enhancement and Evaluation of a Small Female Hybrid III Pregnant Dummy",
journal="Proceedings of the International Research Council on the Biomechanics of Injury conference",
year="2006",
author="Zhao, Y. and Yao, C. and Brill, G. and Goldner, S. and Huang, R.",
volume="34",
number="",
pages="-",
abstract="The MAMA-2B (Maternal Anthropomorphic Measurement Apparatus, version 2B), a small female Hybrid III pregnant dummy used to study the safety of a fetus and effects of seat belt and airbags has been evaluated and enhanced. Two IR-TRACCs (Infra-Red Telescoping Rod for the Assessment of Chest Compression) have been added to measure the chest deflection. A potentiometer was added to measure the IR-TRACC rotation. Two accelerometers have also been added for the chest Viscous Criterion (V*C) calculation. The water-filled abdomen bladder was evaluated. The center of gravity of the slouch posture of the dummy was estimated. Certification tests were conducted and the corridors have been proposed.<p />",
language="en",
issn="2235-3151",
doi="",
url="http://dx.doi.org/"
}