@article{ref1,
title="Performance testing of the Eberline RMS-II criticality accident monitor",
journal="Health physics",
year="1997",
author="Olsher, R. H.",
volume="73",
number="3",
pages="518-521",
abstract="The Plutonium Facility at Los Alamos uses Eberline RMS-II monitors as part of its criticality accident alarm system. The monitors are designed to accommodate a wide spectrum of criticality accident scenarios from both liquid and metal supercriticalities. A series of experiments were performed at the Los Alamos Critical Experiments Facility to evaluate the response of the monitor to a wide range of radiation transients. The primary objectives of the evaluation were to verify reliable and prompt latching of the criticality alarms in accordance with the performance criteria of ANSI/ANS-8.3-1986. The RMS-II monitor performed reliably during all of the experiments and was found to meet specific ANSI/ANS performance criteria for latching.<p /><p>Language: en</p>",
language="en",
issn="0017-9078",
doi="",
url="http://dx.doi.org/"
}