@article{ref1,
title="The impact of various rehydration volumes for firefighters wearing protective clothing in warm environments",
journal="Ergonomics",
year="2006",
author="Selkirk, G. A. and McLellan, T. M. and Wong, John",
volume="49",
number="4",
pages="418-433",
abstract="This study examined different fluid replacement quantities during intermittent work while wearing firefighting protective clothing and self-contained breathing apparatus in the heat (35 degrees C, 50% relative humidity). Twelve firefighters walked at 4.5 km per h with 0% elevation on an intermittent work (50 min) and rest (30 min) schedule until they reached a rectal temperature of 39.5 degrees C during work periods and 40.0 degrees C during rest, heart rates of 95% of maximum and/or exhaustion. During the heat-stress trials subjects received one of four fluid replacement quantities, high (H), moderate (M), low (L), and no hydration (NH), where H, M and L represented 78%, 63% and 37% of fluid loss, respectively. The total tolerance time (work + rest) was significantly greater during H (111.8 +/- 3.5), M (112.9 +/- 5.2) and L (104.2 +/- 5.8) compared to NH (95.3 +/- 3.8). In addition, work time (min), which excluded rest periods, was significantly greater in H (82.6 +/- 3.5), and M (82.9 +/- 5.2) compared to NH (65.3 +/- 3.8). It is concluded that incorporating even partial fluid replacement strategies while wearing firefighting protective clothing and self-contained breathing apparatus in the heat improves tolerance time.<p /> <p>Language: en</p>",
language="en",
issn="0014-0139",
doi="10.1080/00140130600558007",
url="http://dx.doi.org/10.1080/00140130600558007"
}