title="Measurement Accuracy of the Electrosensitive Protective Device Response Time When Using the Double Penetration Method",
journal="International journal of occupational safety and ergonomics",
year="1998",
author="Dzwiarek, Marek",
volume="4",
number="3",
pages="363-384",
abstract="The Double Penetration Method (DPM) method of measuring ESPD (Electrosensitive Protective Device) response time was presented by D wiarek (1997). Calibrating the measuring equipment is a crucial stage of the procedure. Experimental verification of theoretical predictions is also crucial. For calibration purposes, a device simulating real ESPD operation thus enabling a correct setting of the response time was designed (Dzwiarek, 1997). Theoretical analysis has shown that measuring ESPD response time with the DPM is subject to localisation errors made in the localisation of the detection zone border, rod position measurement errors made during high-speed penetration, and time delay measurement errors. The values of all those components of the total error have been determined experimentally using the calibrating device. Measurements have been taken under conditions as close to real ones as possible proving that the total measurement error is really enclosed within the assumed limits.<p /> <p>Language: en</p>",