title="Shielding analysis of the Microtron MT-25 bunker using the MCNP-4C code and NCRP Report 51",
journal="Radiation protection dosimetry",
year="2004",
author="Casanova, A. O. and López, N. and Gelen, A. and Guevara, M. V. Manso and Díaz, O. and Cimino, L. and D'Alessandro, K. and Melo, J. C.",
volume="109",
number="3",
pages="189-195",
abstract="A cyclic electron accelerator Microtron MT-25 will be installed in Havana, Cuba. Electrons, neutrons and gamma radiation up to 25 MeV can be produced in the MT-25. A detailed shielding analysis for the bunker is carried out using two ways: the NCRP-51 Report and the Monte Carlo Method (MCNP-4C Code). The walls and ceiling thicknesses are estimated with dose constraints of 0.5 and 20 mSv y(-1), respectively, and an area occupancy factor of 1/16. Both results are compared and a preliminary bunker design is shown.<p /><p>Language: en</p>",
language="en",
issn="0144-8420",
doi="10.1093/rpd/nch326",
url="http://dx.doi.org/10.1093/rpd/nch326"
}