@article{ref1,
title="Detecting stumbles with a single accelerometer",
journal="Conference proceedings - IEEE engineering in medicine and biology society",
year="2012",
author="Hajj Chehade, Nabil and Ozisik, Pinar and Gomez, James and Ramos, Fabio and Pottie, Greg",
volume="2012",
number="",
pages="6681-6686",
abstract="Falls are a common problem in the elderly population, and their prediction has been a major interest for the medical field. The relationship between stumbles and falls has not been very well understood yet. A critical requirement in advancing the study of this relationship is the realization of a realistic and effective stumble detection system. In this paper, we present a system for the detection of stumbles during walking. Our system consists of a single low cost triaxial accelerometer that may be worn by patients and is convenient for a wide range of subjects. We formulate the problem as an anomaly detection and we validate our system with a large data set collected from 9 subjects. The data set contains a total of 100 stumbles and 45 minutes of walking. We compare 7 different placements for the accelerometer, and show that our system achieves a 99% detection rate, with a 0.2% false alarm rate using an accelerometer worn on the chest.<p /> <p>Language: en</p>",
language="en",
issn="1557-170X",
doi="10.1109/EMBC.2012.6347527",
url="http://dx.doi.org/10.1109/EMBC.2012.6347527"
}