title="Blood alcohol analysis: Comparison of whole blood analysis by gas chromatography with serum analysis by enzymatic method",
journal="Journal (Canadian Society of Forensic Science)",
year="1989",
author="Shajani, N. K. and Godolphin, W. and Image, B. A.",
volume="22",
number="4",
pages="317-320",
abstract="Venous blood samples drawn from 14 drinking subjects were analyzed by a gas chromatographic (GC) procedure and compared with serum samples analyzed by an automated alcohol dehydrogenase (ADH) based enzymatic assay using a DuPont ACA® Ill Discrete Clinical Analyzer. The conversion factor for serum to whole blood for alcohol was found to be 1.14 (range 1.12-1.18, s.d. 0.015).<p />",