@article{ref1,
title="A quantitative method for the determination of the concentration of alcohol in liquids through the measurement of colour saturation",
journal="Blutalkohol",
year="1978",
author="Blazek, V and Lins, G.",
volume="15",
number="3",
pages="176-185",
abstract="Based on the results of two previous publications a new method is suggested to replace the titration in the original procedure of Widmark which was based on the change in coloric saturation of the liquid under investigation K2Cr2O7 as a function of the alcoholic concentration compared with a blank value. A linear relationship between the two variables is demonstrated both numerically and graphically. The advantages - increased accuracy of 38% - and disadvantages - increased equipment requirements and computation - are pointed out.<p />",
language="de",
issn="0006-5250",
doi="",
url="http://dx.doi.org/"
}