@article{ref1,
title="Effect of different cooling regimes on the mechanical properties of cementitious composites subjected to high temperatures",
journal="ScientificWorldJournal",
year="2014",
author="Yu, Jiangtao and Weng, Wenfang and Yu, Kequan",
volume="2014",
number="",
pages="e289213-e289213",
abstract="The influence of different cooling regimes (quenching in water and cooling in air) on the residual mechanical properties of engineered cementitious composite (ECC) subjected to high temperature up to 800°C was discussed in this paper. The ECC specimens are exposed to 100, 200, 400, 600, and 800°C with the unheated specimens for reference. Different cooling regimens had a significant influence on the mechanical properties of postfire ECC specimens. The microstructural characterization was examined before and after exposure to fire deterioration by using scanning electron microscopy (SEM). <br><br>RESULTS from the microtest well explained the mechanical properties variation of postfire specimens.<p /> <p>Language: en</p>",
language="en",
issn="2356-6140",
doi="10.1155/2014/289213",
url="http://dx.doi.org/10.1155/2014/289213"
}