@article{ref1,
title="Chemical protective clothing breakthrough time: comparison of several test systems",
journal="American Industrial Hygiene Association journal",
year="1988",
author="Berardinelli, S. P. and Moyer, E. S.",
volume="49",
number="3",
pages="89-94",
abstract="This study compared chemical permeation data obtained with a photo-ionization detector in both open- and closed-loop test systems. Also, chemical permeation data obtained at two flow rates with an infrared detector in a closed-loop test system were compared. Breakthrough times for acetone-neoprene were obtained using all systems. <br><br>RESULTS were evaluated and determined to be system dependent.<p /><p>Language: en</p>",
language="en",
issn="0002-8894",
doi="10.1080/15298668891379440",
url="http://dx.doi.org/10.1080/15298668891379440"
}