@article{ref1,
title="Brief summary of the Hungarian test method (MSZ 14800-6:2009) of fire propagation on building façades",
journal="MATEC web of conferences",
year="2016",
author="Móder, István and Varga, Ádám and Geier, Péter and Vágó, Bálint and Rajna, Edit",
volume="46",
number="",
pages="01002-01002",
abstract="When a fully developed fire from one compartment of a building spreads from a window to a façade, it is considered to be one of the most dangerous causes of fire propagation on façades. The Hungarian test method described in standard MSZ 14800-6:2009 focuses on determining the effect and risk evaluation of combustible façade materials by modelling a heat release of a compartment/office fire scenario in a model building with realistic construction and detail types. The method provides actual fire spread limit (Th) in minutes and an evaluation method as well.<p /> <p>Language: en</p>",
language="en",
issn="2261-236X",
doi="10.1051/matecconf/20164601002",
url="http://dx.doi.org/10.1051/matecconf/20164601002"
}