
@article{ref1,
title="When a step is not a step! Specificity analysis of five physical activity monitors",
journal="PLoS one",
year="2017",
author="O'Connell, Sandra and Olaighin, Gearoid and Quinlan, Leo R.",
volume="12",
number="1",
pages="e0169616-e0169616",
abstract="INTRODUCTION: Physical activity is an essential aspect of a healthy lifestyle for both physical and mental health states. As step count is one of the most utilized measures for quantifying physical activity it is important that activity-monitoring devices be both sensitive and specific in recording actual steps taken and disregard non-stepping body movements. The objective of this study was to assess the specificity of five activity monitors during a variety of prescribed non-stepping activities. <br><br>METHODS: Participants wore five activity monitors simultaneously for a variety of prescribed activities including deskwork, taking an elevator, taking a bus journey, automobile driving, washing and drying dishes; functional reaching task; indoor cycling; outdoor cycling; and indoor rowing. Each task was carried out for either a specific duration of time or over a specific distance. Activity monitors tested were the ActivPAL micro™, NL-2000™ pedometer, Withings Smart Activity Monitor Tracker (Pulse O2)™, Fitbit One™ and Jawbone UP™. Participants were video-recorded while carrying out the prescribed activities and the false positive step count registered on each activity monitor was obtained and compared to the video. <br><br>RESULTS: All activity monitors registered a significant number of false positive steps per minute during one or more of the prescribed activities. The Withings™ activity performed best, registering a significant number of false positive steps per minute during the outdoor cycling activity only (P = 0.025). The Jawbone™ registered a significant number of false positive steps during the functional reaching task and while washing and drying dishes, which involved arm and hand movement (P < 0.01 for both). The ActivPAL™ registered a significant number of false positive steps during the cycling exercises (P < 0.001 for both). <br><br>CONCLUSION: As a number of false positive steps were registered on the activity monitors during the non-stepping activities, the authors conclude that non-stepping physical activities can result in the false detection of steps. This can negatively affect the quantification of physical activity with regard to step count as an output. The Withings™ activity monitor performed best with regard to specificity during the activities of daily living tested.<p /> <p>Language: en</p>",
language="en",
issn="1932-6203",
doi="10.1371/journal.pone.0169616",
url="http://dx.doi.org/10.1371/journal.pone.0169616"
}