
@article{ref1,
title="Accuracy of ICD-10-CM coding for physical child abuse in a paediatric level I trauma centre",
journal="Injury prevention",
year="2021",
author="Hughes Garza, Holly and Piper, Karen E. and Barczyk, Amanda N. and Perez, Adriana and Lawson, Karla A.",
volume="27",
number="S1",
pages="i71-i74",
abstract="This retrospective study examined the accuracy of the International Classification of Diseases, Clinical Modification (ICD-10-CM) coding for physical child abuse among patients less than 18 years of age who were evaluated due to concern for physical abuse by a multidisciplinary child protection team (MCPT) during 2016-2017 (N=312) in a paediatric level I trauma centre. Sensitivity, specificity, predictive values and diagnostic OR for ICD-10-CM coding were calculated and stratified by admission status, using as a reference standard the abuse determination of the MCPT recorded in a hospital registry. Among inpatients, child physical abuse coding sensitivity was 55.6% (95% CI 41.4% to 69.1%) and specificity was 78.6% (95% CI 59.0% to 91.7%), with diagnostic OR of 4.58 (95% CI 1.64 to 12.70). Among outpatients, sensitivity was 22.2% (95% CI 15.5% to 30.2%) and specificity was 86.3% (95% CI 77.7% to 92.5%), with diagnostic OR of 1.80 (95% CI 0.89 to 3.64). Use of ICD-10-CM coded data sets alone for surveillance may significantly underestimate the occurrence of physical child abuse.<p /> <p>Language: en</p>",
language="en",
issn="1353-8047",
doi="10.1136/injuryprev-2019-043513",
url="http://dx.doi.org/10.1136/injuryprev-2019-043513"
}