@article{ref1,
title="Experimental study on occurrence limit heat release rate of flashover in a building fire",
journal="Journal of the Korean Society of Hazard Mitigation",
year="2021",
author="강, 승구 and 신, 이철",
volume="21",
number="2",
pages="65-71",
abstract="In this study, to allow the flashover to occur, combustion tests were conducted by setting the conditions of a fire source using a large-scale compartment and changing the opening condition. As a result, the inside temperature of the compartment was measured under the fire source conditions. Moreover, according to the &quot;Handbook on Design Calculation Methods of Fire Behavior&quot; by the Architectural Institute of Japan, the validity of the heat release rate required for the flashover to occur was verified through the correlation between QFO /Qvmax and AT (kρc)1/2 /cp 0.5AH1/2.   Keywords: Large-Scale, Fire Compartment Temperature, Flash Over, Heat Release Rate  ===  본 연구에서는 플래시오버가 발생할 수 있도록 실규모 화재구획실을 이용하여 화원조건을 설정하고 개구조건을 변화시켜 연소실험을 실시하였다. 그 결과, 화원조건에 따른 화재실의 내부온도를 수집하였고, 또한, 일본건축학회 화재성상예측 계산 핸드북에서 제시하고 있는QFO /Qvmax 와AT (kρc)1/2 /cp 0.5AH1/2 의 상관관계를 통한 플래시오버 발생한계 열방출률에 대한 유효성을 확인하였다.<p /> <p>Language: ko</p>",
language="ko",
issn="1738-2424",
doi="10.9798/KOSHAM.2021.21.2.65",
url="http://dx.doi.org/10.9798/KOSHAM.2021.21.2.65"
}