@article{ref1,
title="A study on the static structural strength evaluation of 53ft liquefied natural gas tank container",
journal="Journal of the Society of Naval Architects of Korea",
year="2023",
author="심천식,  and 김호경,  and 정다슬,  and 이덕연,  and 김강호,  and 김민석,  and 위성국,  and 노희창,  and 권영빈,  and 홍창석,  and 김병화,  and 김청학, ",
volume="60",
number="4",
pages="278-287",
abstract="This study aims to analyze and evaluate the structural strength of a 53ft Liquefied Natural Gas (LNG) tank container according to International Organization for Standardization (ISO) 1496-3, amidst growing global demand for LNG transportation. The research was conducted in two main stages: structural analysis using Finite Element Analysis (FEA) under various load conditions, and structural strength tests following ISO 1496-3 test procedures. The structural analysis was performed considering different loading conditions to assess the structural safety of the tank container. Calculated stresses were compared with allowable stress under specified load conditions. The structural strength tests were conducted at Mokpo National University<p /> <p>Language: ko</p>",
language="ko",
issn="1225-1143",
doi="10.3744/SNAK.2023.60.4.278",
url="http://dx.doi.org/10.3744/SNAK.2023.60.4.278"
}