@article{ref1,
title="Probe electrospray ionization tandem mass spectrometry for the detection and quantification of benzodiazepines",
journal="Therapeutic drug monitoring",
year="2024",
author="Griffeuille, Pauline and El Balkhi, Souleiman and Dulaurent, Sylvain and Saint-Marcoux, Franck",
volume="ePub",
number="ePub",
pages="ePub-ePub",
abstract="BACKGROUND: Legally prescribed benzodiazepines (BZDs) and designer BZDs are widely misused and must be determined in multiple contexts (eg, overdose, drug-facilitated sexual assaults, or driving under the influence of drugs). This study aimed to develop a method for measuring serum BZD levels using probe electrospray ionization (PESI) mass spectrometry and an isotope dilution approach. <br><br>METHODS: A tandem mass spectrometer equipped with a probe electrospray ionization source in multiple reaction monitoring mode was used. Isotope dilution was applied for quantification using a deuterated internal standard at a fixed concentration for alprazolam, bromazepam, diazepam, nordiazepam, oxazepam, temazepam, zolpidem, and zopiclone. This method included designer BZDs: clonazolam, deschloroetizolam, diclazepam, etizolam, flualprazolam, flubromazepam, flubromazolam, meclonazepam, nifoxipam, and pyrazolam. Sample preparation was done by mixing 10 µL of serum with 500 µL of an ethanol/ammonium formate 0.01 mol/L buffer. Complete validation was performed, and the method was compared with liquid chromatography coupled with mass spectrometry (LC-MS/MS) and immunoassays (IC) by analyzing 40 real samples. <br><br>RESULTS: The analysis time for identification and quantification of the 18 molecules was 2.5 minutes. This method was fully validated, and the limits of quantification varied from 5 to 50 mcg/L depending on the molecule. In the 40 real samples, 100% of molecules (n = 89) were detected by both LC-MS/MS and PESI-MS/MS, and regression analysis showed excellent agreement between the 2 methods (r2 = 0.98). On IC, bromazepam and zolpidem were not detected in 2 and 1 cases, respectively. <br><br>CONCLUSIONS: PESI-MS/MS allows serum BZD detection and measurement. Given the isotope dilution approach, a calibration curve was not required, and its performance was similar to that of LC-MS/MS, and its specificity was higher than that of IC.  Keywords: Drug impaired driving <p /> <p>Language: en</p>",
language="en",
issn="0163-4356",
doi="10.1097/FTD.0000000000001189",
url="http://dx.doi.org/10.1097/FTD.0000000000001189"
}