@article{ref1,
title="Determination of zopiclone in plasma using column liquid chromatography with ultraviolet detection",
journal="Journal of chromatography",
year="1992",
author="Royer-Morrot, M. J. and Rambourg, M. and Jacob, I. and Bauer, P. and Royer, R. J.",
volume="581",
number="2",
pages="297-299",
abstract="A reversed-phase liquid chromatographic method with ultraviolet detection for the determination of zopiclone in plasma is described. It is rapid, sensitive, reproducible and linear over a wide range. The method was used to study plasma zopiclone concentrations in a case of acute intoxication after oral ingestion of 300 mg of the drug. The plasma level was 1600 ng/ml 4.5 h after the dose and the elimination half-life was 3.5 h.<p /><p>Language: en</p>",
language="en",
issn="",
doi="10.1016/0378-4347(92)80286-y",
url="http://dx.doi.org/10.1016/0378-4347(92)80286-y"
}