%0 Journal Article
%T Application of the digraph method of fault tree construction to process plant
%J Reliability engineering
%D 1986
%A Andrews, J.D.
%A Morgan, J.M.
%V 14
%N 2
%P 85-106
%X This paper describes the digraph method of fault tree construction and its application to the process stream of a butane vaporiser. It is shown that an accurate, well-structured fault tree can be produced for a process system which incorporates a number of control loops.<p />
%G 
%I Elsevier Publishing
%@ 0143-8174
%U http://dx.doi.org/10.1016/0143-8174(86)90045-4