TY - JOUR PY - 2010// TI - Thermal parameters measurement on fire fighter: Improvement of the monitoring system JO - Conference proceedings - IEEE engineering in medicine and biology society A1 - Oliveira, A. A1 - Gehin, C. A1 - Massot, B. A1 - Ramon, C. A1 - Dittmar, A. A1 - McAdams, E. SP - 6453 EP - 6456 VL - 2010 IS - N2 - Real time monitoring of the thermal parameters on firefighter when operating is one of the ProeTEX project goals. The newly developed equipments in the framework of this project, integrate one temperature sensor and one heat flux sensor in the rescuer's outer garment. The environment in which firefighters operate is dangerous and the thermal risks can occur everywhere. Consequently the heat flux is so not necessarily symmetrical. To improve the thermally at risk situation detection, a modified platinum sensors array was integrated in the jacket in order to monitor simultaneously heat flux and temperature surrounding the rescuer. The sensors were placed in the most exposed area (shoulders and chest) to monitor thermal parameter in different directions. The heat flux is calculated from the temperature difference. This sensors array enables the detection of temperature increases and heat flux even when the heat source is localized on one side.

Language: en

LA - en SN - 1557-170X UR - http://dx.doi.org/10.1109/IEMBS.2010.5627340 ID - ref1 ER -