TY - JOUR PY - 2009// TI - Evaluation of ear-mounted sensors for determining impact head acceleration JO - Proceedings of the International Research Council on the Biomechanics of Injury conference A1 - Panzer, Matthew B. A1 - Bass, Cameron R. A1 - Salzar, Robert S. A1 - Pellettiere, Joseph A1 - Myers, Barry S. SP - 319 EP - 322 VL - 37 IS - N2 - The objective of this study was to compare the coupling of ear-mounted accelerometers with the head during moderate rate and high rate impacts. Impact tests were performed on PMHS equipped with ear-mounted accelerometers and head-mounted accelerometers using a drop tower and a shock tube. Peak head impacts ranged from 130 -350g's for drop tests, and 380-3150g's for shock tube tests. Peak acceleration and HIC values were well correlated between sensors (R2 = 0.87 and 0.76 respectively), an improvement attributed to sensor positioning within the bony canal. A model based on the drop tower data predicted the ear sensor response to within 15% of initial peak measured acceleration.

LA - en SN - 2235-3151 UR - http://dx.doi.org/ ID - ref1 ER -