TY - JOUR PY - 1983// TI - Cervical spine compression responses JO - Proceedings of the International Research Council on the Biomechanics of Injury conference A1 - Mcelhaney, J.h. A1 - Paver, J.g. A1 - McCrackin, H.j. A1 - Maxwell, G.m. SP - 163 EP - 178 VL - 11 IS - N2 - Time-varying compressive loading was applied to unembalmed human cervical spines using an MTS closed-loop hydraulic testing machine. Load programs included relaxation, cyclic loading, variable rate constant velocity loading (0.13-64 cm/sec), and constant velocity loading to failure. The failures produced were similar to those observed clinically. A generalized quasi-linear viscoelastic Maxwell-Weichert model incorporating a continuous relaxation spectrum was developed to predict the relaxation and constant velocity test responses. The fit was adequate considering the complexity of the structure involved. (Author/TRRL)
LA - en SN - 2235-3151 UR - http://dx.doi.org/ ID - ref1 ER -