TY - JOUR PY - 1997// TI - Performance testing of the Eberline RMS-II criticality accident monitor JO - Health physics A1 - Olsher, R. H. SP - 518 EP - 521 VL - 73 IS - 3 N2 - The Plutonium Facility at Los Alamos uses Eberline RMS-II monitors as part of its criticality accident alarm system. The monitors are designed to accommodate a wide spectrum of criticality accident scenarios from both liquid and metal supercriticalities. A series of experiments were performed at the Los Alamos Critical Experiments Facility to evaluate the response of the monitor to a wide range of radiation transients. The primary objectives of the evaluation were to verify reliable and prompt latching of the criticality alarms in accordance with the performance criteria of ANSI/ANS-8.3-1986. The RMS-II monitor performed reliably during all of the experiments and was found to meet specific ANSI/ANS performance criteria for latching.

Language: en

LA - en SN - 0017-9078 UR - http://dx.doi.org/ ID - ref1 ER -