TY - JOUR PY - 1998// TI - Laser ignition of traumatically embedded firework debris JO - Lasers in surgery and medicine A1 - Taylor, C. R. SP - 157 EP - 158 VL - 22 IS - 3 N2 - BACKGROUND AND OBJECTIVE: The Q-switched ruby laser (QSRL) has a good track record for traumatic tattoo removal. An unusual case of QSRL-treatment of a traumatic tattoo composed of firework debris is presented. STUDY DESIGN/PATIENT AND METHOD: A young man's traumatic tattoo, composed of firework debris, underwent QSRL ablation at 4-7 J/cm2 (pulse width 5 mm; duration 20 ns). RESULTS: Each test pulse produced visible sparks and focal projectile ejection of skin with pox-like scar formation. CONCLUSION: Caution is advised when using the QSRL for the treatment of traumatic tattoos composed of potentially combustible debris.
Language: en
LA - en SN - 0196-8092 UR - http://dx.doi.org/ ID - ref1 ER -