TY - JOUR PY - 2012// TI - Acute lung injury following refrigeration coil deicing JO - Clinical toxicology (Philadelphia, Pa.) A1 - McKeown, Nathanael J. A1 - Burton, Brent T. SP - 218 EP - 220 VL - 50 IS - 3 N2 - We report a case of a worker who developed ALI requiring mechanical ventilatory support after attempting to melt ice condensate by applying the flame of an oxy-acetylene torch to refrigeration coils charged with a halocarbon refrigerant in a closed environment. A discussion of possible etiologies are discussed, including phosgene, carbonyl fluoride, and nitrogen oxides. Primary prevention with adequate respiratory protection is recommended whenever deicing is performed in a closed space environment.

Language: en

LA - en SN - 1556-3650 UR - http://dx.doi.org/10.3109/15563650.2012.659251 ID - ref1 ER -