TY - JOUR PY - 2014// TI - Study on factors affecting evacuation capability of a fire-protection walk in underground buildings JO - Procedia engineering A1 - Ji, Jing-wei A1 - Meng, Yao A1 - Li, Qing-jie A1 - Yang, Shao-fan SP - 357 EP - 363 VL - 71 IS - N2 - To investigate the evacuation capability of a fire-protection walk in underground buildings, a typical fire district connected with a fire- protection walk and a stair was set. Evacuation time for 388 people escaping from the area was simulated numerically. Simulation results that the width of all exits in a fire district, the distance between exit of the fire district and the entrance of the stair leading to the out space (walking distance in a fire-protection evacuation walk), the width of the stairs have great effects on evacuation time when the width of the fire-protection evacuation walk was determined. The largest capacity of evacuation can be reached when the exit width is almost the same or wider than the width of the fire-protection evacuation walk. Set the stair and its doors as wide as the fire-protection evacuation walk and a reasonable walking length in a fire-protection walk can prevent forming congestions near these doors.
LA - en SN - 1877-7058 UR - http://dx.doi.org/10.1016/j.proeng.2014.04.051 ID - ref1 ER -