TY - JOUR PY - 2010// TI - Application of four different football match analysis systems: a comparative study JO - Journal of sports sciences A1 - Randers, Morten B. A1 - Mujika, IƱigo A1 - Hewitt, Adam A1 - Santisteban, Juanma A1 - Bischoff, Rasmus A1 - Solano, Roberto A1 - Zubillaga, Asier A1 - Peltola, Esa A1 - Krustrup, Peter A1 - Mohr, Magni SP - 171 EP - 182 VL - 28 IS - 2 N2 - Using a video-based time-motion analysis system, a semi-automatic multiple-camera system, and two commercially available GPS systems (GPS-1; 5 Hz and GPS-2; 1 Hz), we compared activity pattern and fatigue development in the same football [soccer] match. Twenty football players competing in the Spanish second and third divisions participated in the study. Total distance covered during the match for the four systems was as follows: 10.83 + or - 0.77 km (semi-automatic multiple-camera system, n = 20), 9.51 + or - 0.74 km (video-based time-motion analysis system, n = 17), 10.72 + or - 0.70 km (GPS-1, n = 18), and 9.52 + or - 0.89 km (GPS-2, n = 13). Distance covered by high-intensity running for the four systems was as follows: 2.65 + or - 0.53 km (semi-automatic multiple-camera system), 1.61 + or - 0.37 km (video-based time-motion analysing system), 2.03 + or - 0.60 km (GPS-1), and 1.66 + or - 0.44 km (GPS-2). Distance covered by sprinting for the four systems was as follows: 0.38 + or - 0.18 km (semi-automatic multiple-camera system), 0.42 + or - 0.17 km (video-based time-motion analysing system), 0.37 + or - 0.19 km (GPS-1), and 0.23 + or - 0.16 km (GPS-2). All four systems demonstrated greater (P < 0.05) total distance covered and high-intensity running in the first 15-min period and less (P < 0.05) total distance covered and high-intensity running during the last 15-min period than all other 15-min intervals, with a reduction (P < 0.05) in high-intensity running from the first to the last 15-min period of 46 + or - 19%, 37 + or - 26%, 50 + or - 26%, and 45 + or - 27% for the semi-automatic multiple-camera system, video-based time-motion analysis system, GPS-1, and GPS-2, respectively. Our results show that the four systems were able to detect similar performance decrements during a football game and can be used to study game-induced fatigue. Rather large between-system differences were present in the determination of the absolute distances covered, meaning that any comparisons of results between different match analysis systems should be done with caution.
Language: en
LA - en SN - 0264-0414 UR - http://dx.doi.org/10.1080/02640410903428525 ID - ref1 ER -