TY - JOUR PY - 2005// TI - One-sided flame spread phenomena of a thermally thin composite cotton/fiberglass fabric JO - Fire and materials A1 - Kleinhenz, J A1 - Ferkul, P A1 - Pettegrew, R A1 - Sacksteder, KR A1 - T'Ien, JS SP - 27 EP - 37 VL - 29 IS - 1 N2 - As an experimental necessity. past flame spread studies have relied on fast burning cellulosic papers.. For the longer duration tests planned for the International Space Station a 50% fiberglass. 50% cotton composite fabric is better suited for the novel fuel feeding system in the compact hardware design of a Current microgravity combustion experiment. The fabric's combustion characteristics in normal gravity include unexpected cases where a flame can be sustained on one side of the fuel. One-sided flames are smaller in size than their two-sided counterparts, and propagate at half the speed. Surface temperatur distributions were measured using infrared imaging and indicated a high temperature region caused by the non-flammable fiberglass. Breaching the fiberglass matrix made it possible for the flame to transfer to the other side of the fuel. suggesting that the fiberglass matrix acts as a flame arrester.
LA - SN - 0308-0501 UR - http://dx.doi.org/ ID - ref1 ER -