TY - JOUR PY - 2015// TI - Characterisation of the fuel and fire environment in southern Ontario's tallgrass prairie JO - International journal of wildland fire A1 - Kidnie, Susan A1 - Wotton, B. Mike SP - 1118 EP - 1128 VL - 24 IS - 8 N2 - Prescribed burning can be an integral part of tallgrass prairie restoration and management. Understanding fire behaviour in this fuel is critical to conducting safe and effective prescribed burns. Our goal was to quantify important physical characteristics of southern Ontario's tallgrass fuel complex prior to and during prescribed burns and synthesise our findings into useful applications for the prescribed fire community. We found that the average fuel load in tallgrass communities was 0.70 kg m-2. Fuel loads varied from 0.38 to 0.96 kg m-2. Average heat of combustion did not vary by species and was 17 334 kJ kg-1. A moisture content model was developed for fully cured, matted field grass, which was found to successfully predict moisture content of the surface layers of cured tallgrass in spring. We observed 25 head fires in spring-season prescribed burns with spread rates ranging from 4 to 55 m min-1. Flame front residence time averaged 27 s, varying significantly with fuel load but not fire spread rate. A grassland spread rate model from Australia showed the closest agreement with observed spread rates. These results provide prescribed-burn practitioners in Ontario better information to plan and deliver successful burns.

Language: en

LA - en SN - 1049-8001 UR - http://dx.doi.org/10.1071/WF14214 ID - ref1 ER -