TY - JOUR PY - 2021// TI - Performance of fire breaks installed within EPS-insulated façade systems JO - Fire and materials A1 - Lalu, Octavian A1 - Lennon, Tom A1 - Darmon, Ruxandra A1 - Anghel, Ion SP - 638 EP - 647 VL - 45 IS - 5 N2 - External Thermal Insulation Composite Systems (ETICS) are used in most European countries for the thermal rehabilitation of existing buildings or as a method to improve the thermal performance of new constructions. This paper describes an ad-hoc intermediate-scale experimental study to evaluate the behavior of ETIC systems in case of a fire and shows the impact of different positions and types of fire breaks on global performance. The intention of this experimental intermediate scale methodology is to be used as a screening test and not to replace or reproduce the large-scale testing regime. The results of this study show that interruption of the combustible insulation may have a contribution in limiting the vertical fire spread and can significantly reduce the damaged area affected by the heat exposure.

Language: en

LA - en SN - 0308-0501 UR - http://dx.doi.org/10.1002/fam.2972 ID - ref1 ER -