TY - JOUR PY - 2023// TI - Biokinetic model analysis with DTPA administration for a case of accidental inhalation of actinides in Japan JO - Radiation protection dosimetry A1 - Tani, Kotaro A1 - Ishigure, Nobuhito A1 - Kim, Eunjoo A1 - Tominaga, Takako A1 - Tatsuzaki, Hideo A1 - Akashi, Makoto A1 - Kurihara, Osamu SP - 2025 EP - 2029 VL - 199 IS - 15-16 N2 - Accidental inhalation intake of plutonium isotopes and 241Am occurred at a Pu research facility in Japan in 2017, and the five workers involved in this accident were treated by the administration of Ca/Zn-diethylenetriaminepentaacetic acid (DTPA). For the worker who was most internally exposed, the therapy was continued over 1 y after the accident. Urinary samples collected before and after each administration were subject to bioassay to evaluate the efficacy of the dose reduction. This study performed numerical analyses using a biokinetic model dealing with 241Am-DTPA with reference to the European Coordinated Network on Radiation Dosimetry approach, which assumes that the complex of actinides and Ca/Zn-DTPA is generated in the designated compartments in the biokinetic model. The results of the model prediction well captured the trend of the observed urinary excretion in the long-term bioassay and would be useful to evaluate the efficacy of the Ca/Zn-DTPA administration for the worker involved in the accident.
Language: en
LA - en SN - 0144-8420 UR - http://dx.doi.org/10.1093/rpd/ncac224 ID - ref1 ER -