TY - JOUR PY - 2024// TI - Extubation failure: upper airway obstruction by chewing gum: a case report JO - Revista española de anestesiología y reanimación (English edition) A1 - Gonzalez-Anton, D. A1 - Gallice, T. A1 - Borges Da Silva, A. A1 - Carrié, C. SP - ePub EP - ePub VL - ePub IS - ePub N2 - Extubation failure can result from different complications, mostly well described in the literature such as laryngeal edema. Airway obstruction by foreign bodies is a less frequent and unexpected complication and its detection remains a challenge to healthcare professionals. In this case-report, we describe a patient admitted in an intensive care unit following a motor vehicle accident and who underwent an extubation failure and tracheostomy placement due to a misdiagnosed obstruction of a foreign body in the upper airway. Thus, screening of foreign bodies should be considered with a careful interpretation of medical imagery and clinical evaluation in these patients. Finally, cuff leak test, ultrasonography and videolaryngoscopy can be important adjuvants to the identification of suspected foreign bodies.

Language: en

LA - en SN - 2341-1929 UR - http://dx.doi.org/10.1016/j.redare.2024.02.006 ID - ref1 ER -