TY - JOUR PY - 2008// TI - A method for assessing the potential for a dermal burn hazard from malfunctioning consumer electronic devices JO - Journal of burn care and research A1 - Mikolajczak, Celina J. A1 - Taylor, P. M. SP - 338 EP - 345 VL - 29 IS - 2 N2 - We developed an approach to adapt the ASTM C1055-03 Standard to assess the potential for contact burn injury from portable consumer electronic devices. The approach involves measuring the maximum temperature profile during the fault and devising a way to reproduce these temperatures in an exemplar device in a controlled manner for thermesthesiometer measurements. By comparing the results of the thermesthesiometer measurements to the contact burn injury threshold data published in ASTM C1055-03 and various guidelines for unintentional contact times, we were able to predict whether a potential hazard exists and verify result with"finger tests."We applied this method on a number of occasions to assess the likelihood of a contact burn injury resulting from a fault arising inside portable consumer electronic devices.