Sheaff AK, Bennett A, Hanson ED, Kim YS, Hsu J, Shim JK, Edwards ST, Hurley BF. J. Strength Cond. Res. 2010; 24(11): 3112-3122.

Affiliation

1Department of Kinesiology, School of Public Health, University of Maryland, College Park, Maryland; 2Center for Firefighter Safety Research and Development, University of Maryland, College Park, Maryland; and 3Maryland Fire and Rescue Institute, University of Maryland, College Park, Maryland.

Copyright

(Copyright © 2010, National Strength and Conditioning Association)

DOI

10.1519/JSC.0b013e3181f0a8d5

PMID

20938354

Abstract

Sheaff, AK, Bennett, A, Hanson, ED, Kim, Y-S, Hsu, J, Shim, JK, Edwards, ST, and Hurley, BF. Physiological determinants of the candidate physical ability test in firefighters. J Strength Cond Res 24(x): 000-000, 2010-The purpose of this study was to examine the relative importance of physiological characteristics during firefighting performance, as assessed by the Candidate Physical Ability Test (CPAT). Subjects included career and volunteer firefighters aged 18-39 (N = 33). Upper- and lower-body strength, muscle endurance, lower body muscle power, body composition analysis, aerobic capacity, anaerobic fitness, and the heart rate (HR) and blood pressure response to stair climbing were assessed to determine the physiological characteristics of the subjects. To quantify firefighting performance, the CPAT was administered by members of the fire service. Absolute and relative mean power during the Wingate anaerobic cycling test (WAnT), relative peak power during the WAnT, and absolute maximal oxygen uptake (&OV0312;o2max) were significantly higher in those who passed the CPAT (N = 18), compared to those who failed (N = 15; p < 0.01). Mean power during the WAnT, fatigue index during WAnT, absolute &OV0312;o2max, upper body strength, grip strength, and the HR response to stair climbing were significantly related to CPAT performance time (p < 0.01). Absolute &OV0312;o2max and anaerobic fatigue resistance during WAnT best predicted CPAT performance (Adj. R = 0.817; p < 0.001). Performance on the ceiling breach and pull was the only CPAT task that was not significantly related to the physiological characteristics assessed. Measures of anaerobic and cardiovascular fitness best predict overall CPAT performance, and individual task performance. Remedial programs aimed at improving firefighting performance should target anaerobic and aerobic fitness qualities.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print