Chaturvedi AK, Sanders DC, Endecott BR, Ritter RM. J. Appl. Toxicol. 1995; 15(5): 357-363.

Affiliation

Toxicology and Accident Research Laboratory (AAM 610), Federal Aviation Administration, US Department of Transportation, Oklahoma City, OK 73125-5066, USA.

Copyright

(Copyright © 1995, John Wiley and Sons)

DOI

unavailable

PMID

8666718

Abstract

Carbon monoxide (CO) and hydrogen cyanide (HCN) are generated during aircraft interior fires in sufficient amounts to incapacitate cabin occupants. For typical post-crash and in-flight fires, minimum protection periods of 5 and 35 min, respectively, have been suggested for breathing devices to protect the occupants from smoke. Relationships of blood carboxyhemoglobin (COHb) and cyanide (CN-) levels to incapacitation have not been well defined for these gases. Therefore, time to incapacitation (ti) and blood COHb and CN- at incapacitation were examined in rats exposed to CO (5706 ppm for 5-min ti; 1902 ppm for 35-min ti), HCN (184 ppm for 5-min ti; 64 ppm for 35-min ti) and their mixtures (equipotent concentrations of each gas that produced 5- and 35-min ti). Blood CO and HCN uptakes were evaluated at the two concentrations of each gas. With either gas, variation in ti was higher for the 35-min ti than the 5-min ti The COHb level reached a plateau prior to incapacitation at both CO concentrations, and COHb levels at the 5- and 35-min ti were different from each other. Blood CN- increased as a function of both HCN concentration and exposure time, but CN- at the 5-min ti was half of the 35-min ti CN- level. The HCN uptake at the high concentration was about three times that at the low concentration. In the high concentration CO-HCN mixture, ti was shortened from 5 to 2.6 min; COHb dropped from 81 to 55% and blood CN- from 2.3 to 1.1 microgram ml(-1). At the low-concentration CO-HCN mixture, where ti was reduced from 35 to 11.1 min, COHb decreased from 71 to 61% and blood CN- from 4.2 to 1.1 microgram ml(-1). Any alteration in the uptake of either gas by the presence of the other was minimal. Our findings suggest that specific levels of blood COHb and CN- cannot be correlated directly with the incapacitation onset and that postmortem blood COHb and CN- levels should be evaluated carefully in fire victims.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print