SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Stocchetti N, Croci M, Spagnoli D, Gilardoni F, Resta F, Colombo A. J. Neurol. Neurosurg. Psychiatry 2000; 68(1): 14-17.

Affiliation

Neuroscience Intensive Care, Policlinico Hospital IRCCS Milano, Italy. stocchet@polic.cilea.it

Copyright

(Copyright © 2000, BMJ Publishing Group)

DOI

unavailable

PMID

10601394

PMCID

PMC1760611

Abstract

OBJECTIVE: To assess the clinical feasibility and the accuracy of two pragmatic methods in comparison with a conventional computer based method of measurement of masses from CT. METHODS: Nineteen CT scans of 11 patients with severe head injury, showing 34 traumatic lesions, were examined. The volume of every lesion was digitally measured, then a panel of three examiners independently repeated the measurement using the ellipsoid and the Cavalieri method in random order. RESULTS: All the lesions were identified by all the readers and the mean volume measured by each examiner differed by less than 1.5 ml. The average reading time for each scan was 4 minutes for the ellipsoid and 7 minutes for the Cavalieri method. The average volume of the lesions was 34.2 (SD 35) ml with the digital system, and 38.4 (SD 41) ml and 34.8 (SD 36) ml for the ellipsoid and the Cavalieri readings respectively. The average difference between the applied technique and the digital system was 0.57 (SD 9.99) ml for the Cavalieri direct estimator and 0.20 (SD 15.48) ml for the ellipsoid method. The 95% confidence interval for this difference fell between -2.75 and 3.89 ml for the Cavalieri, and between -4.94 and 5.35 ml for the ellipsoid method. There were 19 lesions >25 ml; the ellipsoid method identified 16 of them, whereas 17 were classified with the Cavalieri method. When considering individual lesions rather than the average volume, discrepancies were detected with both methods. The ellipsoid method was less precise, especially when extracerebral lesions were measured. CONCLUSIONS: Both pragmatic methods are inferior to computer based reading, which is the choice when accurate volume estimation is necessary. However, if a digital volumetric determination of the lesions using a CT computer is not possible, the two pragmatic methods offer an alternative.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print