Dsilva AP, Sorensen N. J. Fire Sci. 1996; 14(2): 94-103.

Copyright

(Copyright © 1996, SAGE Publishing)

DOI

unavailable

PMID

unavailable

Abstract

Fundamental studies carried out on the flammability behaviour of trimmings used on soft furnishings have shown that the performance standards, i.e., BS 5867: Part 2: 1980 normally used to assess the flammability performance of fabrics for curtain and drapes is unsuitable for assessing such trimmings. Since trimmings used on soft furnishings are heterogeneous, low weight products, they comprise only a small fraction of the total mass of soft furnishings to which they are attached and so the criteria applied to furnishing fabrics to assess their flammability do not apply to trimmings. A proposed test method takes into consideration the low weight heterogeneous nature of the trimming products in conjunction with their flaming characteristics, e.g., modification to the flame characteristics brought about by the incorporation of flame retardants or flameproofing treatments.