SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Vickery WM, Dascombe BJ, Baker JD, Higham DG, Spratford WA, Duffield R. J. Strength Cond. Res. 2014; 28(6): 1697-1705.

Affiliation

1Applied Sports Science and Exercise Testing Laboratory, School of Environmental and Life Sciences, Faculty of Science and IT, University of Newcastle, Ourimbah, Australia; 2Priority Research Center in Physical Activity and Nutrition, University of Newcastle, Callaghan, Australia; 3Movement Science, Australian Institute of Sport, Canberra, Australia; 4Department of Physiology, Australian Institute of Sport, Canberra, Australia; 5National Institute of Sport Studies, University of Canberra, Canberra, Australia; and 6Sport and Exercise Discipline Group, UTS: Health, University of Technology, Sydney, New South Wales, Australia.

Copyright

(Copyright © 2014, National Strength and Conditioning Association)

DOI

10.1519/JSC.0000000000000285

PMID

24149747

Abstract

The aim of this study was to determine the accuracy and reliability of 5, 10, and 15 Hz global positioning system (GPS) devices. Two male subjects (mean ± SD; age, 25.5 ± 0.7 years; height, 1.75 ± 0.01 m; body mass, 74 ± 5.7 kg) completed 10 repetitions of drills replicating movements typical of tennis, cricket, and field-based (football [soccer]) sports. All movements were completed wearing two 5 and 10 Hz MinimaxX and 2 GPS-Sports 15 Hz GPS devices in a specially designed harness. Criterion movement data for distance and speed were provided from a 22-camera VICON system sampling at 100 Hz. Accuracy was determined using 1-way analysis of variance with Tukey's post hoc tests. Interunit reliability was determined using intraclass correlation (ICC), and typical error was estimated as coefficient of variation (CV). Overall, for the majority of distance and speed measures, as measured using the 5, 10, and 15 Hz GPS devices, were not significantly different (p > 0.05) to the VICON data. Additionally, no improvements in the accuracy or reliability of GPS devices were observed with an increase in the sampling rate. However, the CV for the 5 and 15 Hz devices for distance and speed measures ranged between 3 and 33%, with increasing variability evident in higher speed zones. The majority of ICC measures possessed a low level of interunit reliability (r = -0.35 to 0.39). Based on these results, practitioners of these devices should be aware that measurements of distance and speed may be consistently underestimated, regardless of the movements performed.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print