Manco MR, Vaz MA, Cyrino JCR, Landesmann A. Fire Technol. 2018; 54(6): 1505-1532.

Copyright

(Copyright © 2018, Holtzbrinck Springer Nature Publishing Group)

DOI

10.1007/s10694-018-0750-y

PMID

unavailable

Abstract

This paper presents a model to evaluate the thermal energy transfer between a localized fire and the surfaces exposed to it, without the flame impinging the ceiling of the semi-open compartment. Although this type of fire may not have significant consequences for the structure as a whole, it is capable of triggering other disasters such as explosions and larger fires, which is why its study becomes increasingly important. Currently, this accident is analyzed using either sophisticated or semi-empirical numerical models available in the literature. The former uses computational fluid dynamics (CFD), which acceptably reproduces the fire, although with high computational cost. In turn, the semi-empirical models generally present conservative results. The proposed model presents variants in classic simple models available in the literature with the aim of being a tool that allows designers to estimate the thermal fields resulting from this type of fires at the preliminary structure design stage. In this model, the thermal analysis is performed using a finite element program, considering relevant parameters that characterize the fire such as: heat release rate, location and equivalent diameter of the fire source, among others. Through subroutines, the finite element model considers (a) a modification of hot gases temperature field based in a classic simple model and (b) proposition of a new geometry of the flame. The estimated radiative heat flux employs a solid ellipsoidal flame whose height changes according to the heat release rate. The convective heat flux is evaluated using a model for localized fire. Efficiency and accuracy of the methodology are checked by comparing the simulation results with those obtained by sophisticated models developed in fire dynamic simulator (FDS). The cases studied consider: (a) the replication of the experimental test conducted at LuleƄ University and (b) an offshore platform deck under localized fire action. The results of the first case confirm that the FDS replicates the experimental measurements with high accuracy. Finally, the results show that the proposed model allows to realistically represent the temperature fields generated by the fire, with relatively low computational cost compared to the CFD models for cases (a) and (b), therefore it is possible to use it to develop preliminary analyses in other fire scenarios.


Language: en

Keywords

CFD; FDS; Localized fire; MEF; Modified solid flame model; Pool fire

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print